Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 37
Filter
1.
Asian Journal of Andrology ; (6): 410-415, 2023.
Article in English | WPRIM | ID: wpr-981956

ABSTRACT

The purpose of this study was to explore transrectal ultrasound (TRUS) findings of prostate cancer (PCa) guided by multiparametric magnetic resonance imaging (mpMRI) and to improve the Prostate Imaging Reporting and Data System (PI-RADS) system for avoiding unnecessary mpMRI-guided targeted biopsy (TB). From January 2018 to October 2019, fusion mpMRI and TRUS-guided biopsies were performed in 162 consecutive patients. The study included 188 suspicious lesions on mpMRI in 156 patients, all of whom underwent mpMRI-TRUS fusion imaging-guided TB and 12-core transperineal systematic biopsy (SB). Univariate analyses were performed to investigate the relationship between TRUS features and PCa. Then, logistic regression analysis with generalized estimating equations was performed to determine the independent predictors of PCa and obtain the fitted probability of PCa. The detection rates of PCa based on TB alone, SB alone, and combined SB and TB were 55.9% (105 of 188), 52.6% (82 of 156), and 62.8% (98 of 156), respectively. The significant predictors of PCa on TRUS were hypoechogenicity (odds ratio [OR]: 9.595, P = 0.002), taller-than-wide shape (OR: 3.539, P = 0.022), asymmetric vascular structures (OR: 3.728, P = 0.031), close proximity to capsule (OR: 3.473, P = 0.040), and irregular margins (OR: 3.843, P = 0.041). We propose subgrouping PI-RADS score 3 into categories 3a, 3b, 3c, and 3d based on different numbers of TRUS predictors, as the creation of PI-RADS 3a (no suspicious ultrasound features) could avoid 16.7% of mpMRI-guided TBs. Risk stratification of PCa with mpMRI-TRUS fusion imaging-directed ultrasound features could avoid unnecessary mpMRI-TBs.


Subject(s)
Male , Humans , Prostatic Neoplasms/pathology , Multiparametric Magnetic Resonance Imaging , Magnetic Resonance Imaging/methods , Prostate/pathology , Image-Guided Biopsy/methods
2.
Asian Journal of Andrology ; (6): 217-222, 2023.
Article in English | WPRIM | ID: wpr-971029

ABSTRACT

The Prostate Imaging Reporting and Data System (PI-RADS) has good ability to identify the nature of lesions on prostate magnetic resonance imaging (MRI). However, some lesions are still reported as PI-RADS 4 and 5 but are biopsy-proven benign. Herein, we aimed to summarize the reasons for the negative prostate biopsy of patients who were assessed as PI-RADS 4 and 5 by biparameter MRI. We retrospectively sorted out the prostate MRI, treatment, and follow-up results of patients who underwent a biparameter MRI examination of the prostate in The First Affiliated Hospital of Nanjing Medical University (Nanjing, China) from August 2019 to June 2021 with PI-RADS 4 and 5 but a negative biopsy. We focused on reviewing the MRI characteristics. A total of 467 patients underwent transperineal prostate biopsy. Among them, biopsy pathology of 93 cases were negative. After follow-up, 90 patients were ruled out of prostate cancer. Among the 90 cases, 40 were considered to be overestimated PI-RADS after review. A total of 22 cases were transition zone (TZ) lesions with regular appearance and clear boundaries, and 3 cases were symmetrical lesions. Among 15 cases, the TZ nodules penetrated the peripheral zone (PZ) and were mistaken for the origin of PZ. A total of 17 cases of lesions were difficult to distinguish from prostate cancer. Among them, 5 cases were granulomatous inflammation (1 case of prostate tuberculosis). A total of 33 cases were ambiguous lesions, whose performance was between PI-RADS 3 and 4. In summary, the reasons for "false-positive MRI diagnosis" included PI-RADS overestimation, ambiguous images giving higher PI-RADS, diseases that were really difficult to distinguish, and missed lesion in the initial biopsy; and the first two accounted for the most.


Subject(s)
Male , Humans , Prostatic Neoplasms/pathology , Magnetic Resonance Imaging/methods , Retrospective Studies , Image-Guided Biopsy/methods , Prostate/pathology
3.
Asian Journal of Andrology ; (6): 43-49, 2023.
Article in English | WPRIM | ID: wpr-970989

ABSTRACT

Magnetic resonance imaging (MRI)-targeted prostate biopsy is the recommended investigation in men with suspicious lesion(s) on MRI. The role of concurrent systematic in addition to targeted biopsies is currently unclear. Using our prospectively maintained database, we identified men with at least one Prostate Imaging-Reporting and Data System (PI-RADS) ≥3 lesion who underwent targeted and/or systematic biopsies from May 2016 to May 2020. Clinically significant prostate cancer (csPCa) was defined as any Gleason grade group ≥2 cancer. Of 545 patients who underwent MRI fusion-targeted biopsy, 222 (40.7%) were biopsy naïve, 247 (45.3%) had previous prostate biopsy(s), and 76 (13.9%) had known prostate cancer undergoing active surveillance. Prostate cancer was more commonly found in biopsy-naïve men (63.5%) and those on active surveillance (68.4%) compared to those who had previous biopsies (35.2%; both P < 0.001). Systematic biopsies provided an incremental 10.4% detection of csPCa among biopsy-naïve patients, versus an incremental 2.4% among those who had prior negative biopsies. Multivariable regression found age (odds ratio [OR] = 1.03, P = 0.03), prostate-specific antigen (PSA) density ≥0.15 ng ml-2 (OR = 3.24, P < 0.001), prostate health index (PHI) ≥35 (OR = 2.43, P = 0.006), higher PI-RADS score (vs PI-RADS 3; OR = 4.59 for PI-RADS 4, and OR = 9.91 for PI-RADS 5; both P < 0.001) and target lesion volume-to-prostate volume ratio ≥0.10 (OR = 5.26, P = 0.013) were significantly associated with csPCa detection on targeted biopsy. In conclusion, for men undergoing MRI fusion-targeted prostate biopsies, systematic biopsies should not be omitted given its incremental value to targeted biopsies alone. The factors such as PSA density ≥0.15 ng ml-2, PHI ≥35, higher PI-RADS score, and target lesion volume-to-prostate volume ratio ≥0.10 can help identify men at higher risk of csPCa.


Subject(s)
Male , Humans , Prostate/pathology , Prostatic Neoplasms/pathology , Prostate-Specific Antigen , Magnetic Resonance Imaging/methods , Image-Guided Biopsy/methods , Retrospective Studies
4.
Chinese Journal of Surgery ; (12): 504-508, 2022.
Article in Chinese | WPRIM | ID: wpr-935627

ABSTRACT

Prostate biopsy is the gold standard for the diagnosis of prostate cancer. In order to successfully and effectively complete the biopsy, clinicians should not only select the correct puncture method, but also pay attention to the pain control of patients undergoing puncture. It is necessary to select a reasonable anesthetic method for biopsy. The pain during biopsy comes from the skin, muscle and other structures in the puncture approach, and also comes from the prostate capsule. Therefore, the anesthesia emphasis of transperineal and transrectal biopsy approaches will also be different. The use of appropriate anesthesia is of great significance to improve the patient's cooperation and ensure the success rate of biopsy. With the continuous maturity of the technology and concept of prostate biopsy, a single anesthesia method has been unable to meet the actual anesthetic needs of biopsy, and the use of multi-site and multi-phase combined anesthesia for different sources of pain has become the mainstream anesthetic option.


Subject(s)
Humans , Male , Anesthesia , Anesthesia, Local , Biopsy , Image-Guided Biopsy/methods , Pain/pathology , Prostate/pathology , Prostatic Neoplasms/pathology
5.
Prensa méd. argent ; 107(2): 97-104, 20210000. fig, tab
Article in English | LILACS, BINACIS | ID: biblio-1361373

ABSTRACT

Objetivos: Evaluar la frecuencia y gravedad de la hemorragia parenquimatosa pulmonar tras la biopsia pulmonar con aguja transtorácica coaxial, según factores de procedimiento, aún no descritos en la literatura. El objetivo de este estudio fue determinar si la elección de la tecnología de biopsia coaxial, el posicionamiento del paciente y la dignidad de la lesión son tres nuevas variables que influyen en el riesgo de hemorragia parenquimatosa tras biopsias coaxiales de pulmón. Métodos: Se revisaron retrospectivamente los registros de 117 pacientes que se sometieron a biopsias con aguja transtorácica del pulmón entre enero de 2018 y abril de 2020. El resultado primario fue la hemorragia pulmonar. Se ha utilizado un sistema de clasificación para clasificar la hemorragia parenquimatosa pulmonar: Grado 0 - Grado 3. Se evaluaron tres variables novedosas relacionadas con el paciente, la técnica y la lesión como predictores de hemorragia pulmonar: tecnología de biopsia coaxial, posición del paciente y dignidad de la lesión. Resultados: De los 117 pacientes, 18 (15,4%) pacientes con tecnología de biopsia coaxial de corte, versus 29 (24,8%) pacientes con tecnología coaxial de núcleo completo mostraron hemorragia significativa en las exploraciones de control posteriores a la biopsia. (IC del 95% 0,06-0,33, p <0,0001). No hubo diferencias significativas en la hemorragia pulmonar entre el diagnóstico histológico benigno y maligno (IC 95% 0,84-4,44, p = 0,1199) y la posición del paciente en decúbito prono o supino (IC 95%: 0,57-2,57, p = 0,6232). Conclusiones: La incidencia y gravedad de la hemorragia pulmonar depende de la tecnología de biopsia coaxial utilizada; siendo mayor en pacientes sometidos a una biopsia con tecnología full-core y menor después del uso de tecnología de corte. En este estudio de pronóstico no se estableció una correlación significativa entre la hemorragia pulmonar parenquimatosa y la posición del paciente o la dignidad de la lesión


Objectives: To evaluate the frequency and severity of pulmonary parenchymal hemorrhage after coaxial transthoracic needle biopsy of the lung, according to procedural factors, not yet described in literature. The aim of this study was to determine whether the choice of the coaxial biopsy technology, patient positioning and the lesion dignity are three new variables influencing the risk of parenchymal hemorrhage after coaxial biopsies of the lung. Methods: Records from 117 patients who underwent transthoracic needle biopsies of the lung between January 2018 and April 2020 have been retrospectively reviewed. The primary outcome was pulmonary hemorrhage. A grading system has been used to classify pulmonary parenchymal hemorrhage: Grade 0 ­ Grade 3. Three novel patient, technique and lesion-related variables were evaluated as predictors of pulmonary hemorrhage: coaxial biopsy technology, patient positioning and lesion dignity. Results: Out of the 117 patients, 18 (15,4%) patients with cutting coaxial biopsy technology, versus 29 (24,8%) patients with full core coaxial technology showed significant hemorrhage on the post-biopsy control scans. (95% CI 0,06-0,33, p<0,0001). No significant difference in pulmonary hemorrhage between benign and malignant histological diagnosis (95% CI 0,84-4,44, p=0,1199) and prone or supine patient positioning (95% CI: 0,57-2,57, p= 0,6232) was found. Conclusions: The incidence and severity of pulmonary hemorrhage depends on the coaxial biopsy technology used; being higher in patients undergoing a biopsy with full-core technology and lower after the use of cutting technology. No significant correlation between parenchymal pulmonary hemorrhage and patient positioning or lesion dignity was established in this prognostic study.


Subject(s)
Humans , Prognosis , Tomography, X-Ray Computed , Retrospective Studies , Risk Factors , Lung Injury/therapy , Image-Guided Biopsy/methods , Hemorrhage/prevention & control , Supine Position
6.
Einstein (Säo Paulo) ; 18: eAO4662, 2020. tab, graf
Article in English | LILACS | ID: biblio-1056076

ABSTRACT

ABSTRACT Objective To assess accuracy of multiparametric magnetic resonance of the prostate to estimate gland volume, comparing the results with transrectal ultrasound and surgical specimen. Methods A retrospective study of 85 patients who underwent multiparametric magnetic resonance and transrectal ultrasound (for fusion image-guided biopsy) before radical prostatectomy. Prostate measurements were obtained from magnetic resonance axial and sagittal T2-weighted images and ultrasound; the prostate volume was determined using the ellipsoid formula. The results were compared with the surgical specimen weight. Maximum interval between multiparametric magnetic resonance imaging, transrectal ultrasound, and prostatectomy was 6 months. Results The prostate volume measured by multiparametric magnetic resonance imaging was 18-157cm3 (mean of 49.9cm3) and by transrectal ultrasound, 22-165cm3 (mean of 54.9cm3); the surgical specimen weight was 20-154g (mean of 48.6g), with no statistical differences. Based on the values obtained from imaging examinations, the prostate volume obtained was very close to the real prostatic weight, and the measures by multiparametric magnetic resonance were slightly more precise. Conclusion Prostate volume measured by multiparametric magnetic resonance imaging and transrectal ultrasound showed similar values, and excellent agreement with real prostate weight of the surgical specimens. Prostate volume measured by magnetic resonance has been increasingly used in the clinical practice, and its value enables appropriate therapeutic planning and control of patients.


RESUMO Objetivo Avaliar a acurácia da ressonância magnética multiparamétrica da próstata para estimativa do volume da glândula, comparando seus resultados com a ultrassonografia transretal e correlacionando com o volume obtido da peça cirúrgica. Métodos Estudo retrospectivo incluindo 85 pacientes submetidos à ressonância magnética e, posteriormente, à ultrassonografia transretal (para orientação de biópsia com fusão de imagens) e, a seguir, à prostatectomia radical. As dimensões prostáticas foram obtidas na ressonância a partir das imagens nos planos axial e sagital em sequências ponderadas em T2 e, assim como na ultrassonografia, o volume foi calculado a partir do método da elipsoide. Os valores foram comparados com o peso prostático pós-cirúrgico. O intervalo máximo entre a ressonância e ultrassonografia e prostatectomia foi de 6 meses. Resultados O volume prostático obtido por ressonância magnética foi de 18 a 157cm3(média de 49,9cm3); pela ultrassonografia transretal, foi de 22 a 165cm3(média de 54,9cm3); e o peso da peça cirúrgica foi de 20 a 154g (média de 48,6g), sem diferenças estatísticas. A partir do valor obtido por esses métodos de imagem, provou-se que o volume prostático obtido aproximou-se bastante do peso real da próstata, com discreta maior precisão das medidas obtidas por ressonância magnética multiparamétrica. Conclusão As medidas do volume prostático adquiridas pela ressonância magnética e pela ultrassonografia transretal são semelhantes entre si, com excelente concordância com os pesos reais das próstatas obtidos das peças cirúrgicas. A avaliação desse dado, a partir da ressonância, método cada vez mais utilizado na prática clínica, permite o adequado planejamento terapêutico e o controle dos pacientes.


Subject(s)
Humans , Male , Adult , Aged , Aged, 80 and over , Prostate/anatomy & histology , Prostatic Neoplasms/diagnostic imaging , Ultrasonography/methods , Multiparametric Magnetic Resonance Imaging/methods , Organ Size , Prostate/diagnostic imaging , Prostatectomy , Prostatic Neoplasms/pathology , Retrospective Studies , Image-Guided Biopsy/methods , Dimensional Measurement Accuracy , Middle Aged
7.
Rev. bras. anestesiol ; 69(6): 622-625, nov.-Dec. 2019. tab
Article in English | LILACS | ID: biblio-1057467

ABSTRACT

Abstract Background: Sepsis is a life-threatening organ dysfunction with non-specific clinical features that can mimic other clinical conditions with hyper metabolic state such as malignant hyperthermia. Perioperatively anesthesia providers come across such scenarios, which are extremely challenging with the need for urgent intervention. Objective: To illustrate the need for early intervention and consultation for added assistance to approach and rule out malignant hyperthermia and other possible causes during such a scenario. Case report: A 63-year-old male underwent an uneventful elective flexible cystoscopy and transrectal ultrasound-guided prostate biopsy. Postoperatively he developed symptoms raising suspicion for malignant hyperthermia. Immediately malignant hyperthermia protocol was initiated that included administration of dantrolene and consultation of malignant hyperthermia association hotline along with other diagnostic and interventional management aimed at patient optimization. While early administration of dantrolene helped in hemodynamically stabilizing the patient, the consultation with other providers and malignant hyperthermia association hotline along with repeated examinations and lab works helped in ruling out malignant hyperthermia as the possible diagnosis. The patient later recovered in the intensive care unit where he was treated for the bacteremia that grew in his blood cultures. Conclusions: Sepsis shares clinical symptoms that mimic malignant hyperthermia. While sepsis rapidly progresses to secondary injuries, malignant hyperthermia is life threatening. Providing ideal care requires good clinical judgment and a high level of suspicion where timely and appropriate care such as early administration of dantrolene and consultation of malignant hyperthermia association hotline for added assistance can influence positive outcomes.


Resumo Justificativa: A sepse é uma disfunção orgânica fatal com características clínicas inespecíficas que podem imitar outras condições clínicas com quadro hipermetabólico, como a hipertermia maligna. Os cenários são extremamente desafiadores para a anestesia perioperatória e requerem intervenção urgente. Objetivo: Ilustrar a necessidade de intervenção e consulta precoces para uma assistência adicional na abordagem e exclusão de hipertermia maligna e outras possíveis causas durante tal cenário. Relato de caso: Paciente do sexo masculino, 63 anos, submetido à cistoscopia eletiva com cistoscópio flexível e biópsia transretal da próstata guiada por ultrassom sem intercorrências. No pós-operatório, o paciente desenvolveu sintomas que levantaram a suspeita de hipertermia maligna. O protocolo de hipertermia maligna foi imediatamente iniciado, inclusive a administração de dantrolene e uma consulta pela linha direta da associação de hipertermia maligna, juntamente com outros diagnósticos e manejos intervencionistas com vistas ao aprimoramento do paciente. Enquanto a administração precoce de dantrolene ajudou na estabilização hemodinâmica do paciente, a consulta com outros anestesistas e com a Associação de Hipertermia Maligna, juntamente com repetidos exames físicos e laboratoriais, ajudou a excluir a hipertermia maligna como o possível diagnóstico. O paciente recuperou-se mais tarde na unidade de terapia intensiva, onde recebeu tratamento para a bacteremia detectada em suas hemoculturas. Conclusões: A sepse compartilha sintomas clínicos que mimetizam a hipertermia maligna. Enquanto a sepse progride rapidamente para lesões secundárias, a hipertermia maligna é uma ameaça à vida. Proporcionar o tratamento ideal requer um bom julgamento clínico e um alto nível de suspeita quanto aos cuidados oportunos e apropriados, como a administração precoce de dantrolene e a consulta pela linha direta da Associação de Hipertermia Maligna para assistência adicional, que podem resultar em desfechos positivos.


Subject(s)
Humans , Male , Postoperative Complications/diagnosis , Sepsis/diagnosis , Malignant Hyperthermia/diagnosis , Postoperative Complications/physiopathology , Postoperative Complications/therapy , Time Factors , Acute Disease , Sepsis/physiopathology , Sepsis/therapy , Cystoscopy/methods , Dantrolene/administration & dosage , Image-Guided Biopsy/methods , Malignant Hyperthermia/physiopathology , Middle Aged
8.
Rev. méd. Chile ; 147(10): 1266-1272, oct. 2019. tab, graf
Article in Spanish | LILACS | ID: biblio-1058593

ABSTRACT

Background: CT-guided core biopsy is a widely used diagnostic technique for retroperitoneal lesions. Aim: To evaluate the diagnostic yield and safety of this procedure. Material and Methods: Review of medical records of 136 patients aged 57 ± 16 years (55% males) subjected to core biopsies performed between 2006 and 2016. Procedure images, biopsy reports and patients' medical charts were reviewed. Diagnostic yield was calculated in those patients whose final diagnosis was confirmed using strict criteria for malignancy. Results: A final diagnosis was confirmed in 122/136 patients. Of these, 110 had malignant lesions. The sensitivity and global accuracy of the procedure for malignancy were 93%. In only 4 of 13 benign lesions (31%), a specific diagnosis was obtained with the biopsy. Only minor complications were reported (6 small, self-contained hematomas). There were no major complications. Conclusions: CT-guided core biopsy of retroperitoneal lesions is a safe procedure, with an excellent diagnostic yield.


Subject(s)
Humans , Male , Female , Adolescent , Adult , Middle Aged , Aged , Aged, 80 and over , Young Adult , Retroperitoneal Neoplasms/pathology , Tomography, X-Ray Computed/methods , Image-Guided Biopsy/methods , Retroperitoneal Neoplasms/diagnosis , Retroperitoneal Space/pathology , Radiography, Interventional/methods , Chile , Cross-Sectional Studies , Reproducibility of Results , Retrospective Studies , Sensitivity and Specificity , Statistics, Nonparametric , Biopsy, Large-Core Needle/methods
9.
Int. braz. j. urol ; 45(4): 724-731, July-Aug. 2019. tab, graf
Article in English | LILACS | ID: biblio-1019880

ABSTRACT

ABSTRACT Objectives To evaluate the diagnostic performance and interobserver agreement of PI-RADS v2. Materials and Methods In this Institutional Review Board approved single-center retrospective study, 98 patients with clinically suspected PCa who underwent 3-T multiparametric MRI followed by MRI/TRUS fusion-guided prostate biopsy were included from June 2013 to February 2015. Two radiologists (R1 and R2) with 8 and 1 years of experience in abdominal radiology reviewed the MRI scans and assigned PI-RADS v2 scores in all prostate zones. PI-RADS v2 were compared to MRI/TRUS fusion-guided biopsy results, which were classified as negative, PCa, and significant PCa (sPCa). Results Sensitivity, specificity, NPV, PPV and accuracy for PCa was 85.7% (same for all metrics) for R1 and 81.6%, 79.6%, 81.2%, 80.0% and 80.6% for R2. For detecting sPCa, the corresponding values were 95.3%, 85.4%, 95.9%, 83.7% and 89.8% for R1 and 93.0%, 81.8%, 93.7%, 86.7% and 86.7% for R2. There was substantial interobserver agreement in assigning PI-RADS v2 score as negative (1, 2, 3) or positive (4, 5) (Kappa=0.78). On multivariate analysis, PI-RADS v2 (p <0.001) was the only independent predictor of sPCa compared with age, abnormal DRE, prostate volume, PSA and PSA density. Conclusions Our study population demonstrated that PI-RADS v2 had high diagnostic accuracy, substantial interobserver agreement, and it was the only independent predictor of sPCa.


Subject(s)
Humans , Male , Aged , Prostatic Neoplasms/diagnostic imaging , Magnetic Resonance Imaging/methods , Prostatic Neoplasms/pathology , Reference Values , Brazil , Logistic Models , Observer Variation , Reproducibility of Results , Retrospective Studies , Risk Factors , Sensitivity and Specificity , Prostate-Specific Antigen/blood , Statistics, Nonparametric , Risk Assessment , Neoplasm Grading , Image-Guided Biopsy/methods , Middle Aged
10.
Int. braz. j. urol ; 45(3): 486-494, May-June 2019. tab, graf
Article in English | LILACS | ID: biblio-1012318

ABSTRACT

ABSTRACT Objectives: To identify the group of patients who could safely avoid prostate biopsy based on the findings of multiparametric prostate resonance imaging (MRmp), parameterized with PI-RADS v2, using prostate biopsy as reference test and to assess the sensitivity and specificity of mpMR in identifying clinically significant prostate cancer using prostate biopsy as a reference test. Patients and Methods: Three hundred and forty two patients with suspected prostate cancer were evaluated with mpMR and prostate biopsy. Agreement between imaging findings and histopathological findings was assessed using the Kappa index. The accuracy of mpMR in relation to biopsy was assessed by calculations of sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV). Results: A total of 342 biopsies were performed. In 201 (61.4%), mpMR had a negative result for cancer, which was confirmed on biopsy in 182 (53%) of the cases, 17 (4.9%) presented non-clinically significant cancer and only 2 (0.5%) clinically significant cancer. 131 (38.3%) patients had a positive biopsy. Clinically significant cancer corresponded to 83 (34.2%), of which 81 (97.5%) had a positive result in mpMR. Considering only the clinically significant cancers the mpMR had a sensitivity of 97.6%, specificity of 76.8%, PPV 57.4% and VPN of 99%. Conclusions: mpMR is a useful tool to safely identify which patients at risk for prostate cancer need to undergo biopsy and has high sensitivity and specificity in identifying clinically significant prostate cancer.


Subject(s)
Humans , Male , Female , Adult , Aged , Aged, 80 and over , Prostate/pathology , Prostate/diagnostic imaging , Prostatic Neoplasms/pathology , Prostatic Neoplasms/diagnostic imaging , Magnetic Resonance Imaging/methods , Image-Guided Biopsy/methods , Reference Standards , Reproducibility of Results , Retrospective Studies , Risk Factors , Sensitivity and Specificity , Neoplasm Grading , Middle Aged
11.
Int. braz. j. urol ; 44(6): 1106-1113, Nov.-Dec. 2018. tab, graf
Article in English | LILACS | ID: biblio-975665

ABSTRACT

ABSTRACT Purpose: Ultrasound-magnetic resonance imaging (US-MRI) fusion biopsy (FB) improves the detection of clinically significant prostate cancer (PCa). We aimed to compare the Gleason upgrading (GU) rates and the concordance of the Gleason scores in the biopsy versus final pathology after surgery in patients who underwent transrectal ultrasound (TRUS) systematic random biopsies (SRB) versus US-MRI FB for PCa. Materials and Methods: A retrospective analysis of data that were collected prospectively from January 2011 to June 2016 from patients who underwent prostate biopsy and subsequent radical prostatectomy. The study cohort was divided into two groups: US-MRI FB (Group A) and TRUS SRB (Group B). US-MRI FB was performed in patients with a previous MRI with a focal lesion with a Likert score ≥3; otherwise, a TRUS SRB was performed. Results: In total, 73 men underwent US-MRI FB, and 89 underwent TRUS SRB. The GU rate was higher in Group B (31.5% vs. 16.4%; p=0.027). According to the Gleason grade pattern, GU was higher in Group B than in Group A (40.4% vs. 23.3%; p=0.020). Analyses of the Gleason grading patterns showed that Gleason scores 3+4 presented less GU in Group A (24.1% vs. 52.6%; p=0.043). The Bland-Altman plot analysis showed a higher bias in Group B than in Group A (-0.27 [-1.40 to 0.86] vs. −0.01 [-1.42 to 1.39]). In the multivariable logistic regression analysis, the only independent predictor of GU was the use of TRUS SRB (2.64 [1.11 - 6.28]; p=0.024). Conclusions: US-MRI FB appears to be related to a decrease in GU rate and an increase in concordance between biopsy and final pathology compared to TRUS SRB, suggesting that performing US-MRI FB leads to greater accuracy of diagnosis and better treatment decisions.


Subject(s)
Humans , Male , Aged , Prostatic Neoplasms/diagnostic imaging , Ultrasonography, Interventional , Magnetic Resonance Imaging, Interventional , Image-Guided Biopsy/methods , Prostatectomy , Prostatic Neoplasms/pathology , Retrospective Studies , Cohort Studies , Neoplasm Grading , Middle Aged
12.
Arq. gastroenterol ; 55(3): 208-211, July-Sept. 2018. tab, graf
Article in English | LILACS | ID: biblio-973889

ABSTRACT

ABSTRACT BACKGROUND: Though strongly suggestive of metastasis, focal lesions on liver scans of oncological patients require histological confirmation for the prescription of adequate treatment. OBJECTIVE: To evaluate the safety and efficacy of US-guided percutaneous core liver biopsy. METHODS: Descriptive, cross-sectional study based on secondary data from 171 patients submitted to US-guided percutaneous core liver biopsy at the diagnostic radiology service of the Ceará Cancer Institute (ICC, Brazil) between February 2010 and March 2015. Quantitative data were expressed in absolute numbers or percentages, with emphasis on the rate of complications observed within six hours after the procedure. RESULTS: The overall accuracy was 96.4%. The overall rate of complications was 2.3%, three quarters of which was due to hemorrhage. Age over 50 years was positively associated with accuracy. No deaths occurred within the period of observation. CONCLUSION: Our findings support the claim that the use of thick biopsy needles improves diagnostic accuracy. The few complications observed were non-lethal and predominantly hemorrhagic.


RESUMO CONTEXTO: Lesões focais nos exames de imagem do fígado em pacientes oncológicos, embora sejam achados fortemente sugestivos de envolvimento metastático, permanece a necessidade de confirmação histológica, a fim de que se institua uma terapia apropriada. OBJETIVO: Verificar a segurança e a eficácia do procedimento de biópsia hepática percutânea guiada por ultrassom, realizado pelo serviço de Radiologia e Diagnóstico por Imagem do Instituto do Câncer do Ceará (ICC). MÉTODOS: Estudo transversal, descritivo, baseado em dados secundários de 171 pacientes, submetidos a biópsias hepáticas percutâneas, guiadas por ultrassonografia, realizadas no ICC, de fevereiro de 2010 a março de 2015. Os dados quantitativos obtidos foram apresentados em forma de números absolutos ou percentuais, com ênfase nas taxas de complicações, ocorridas nas primeiras seis horas de observação hospitalar. RESULTADOS: A acurácia geral foi de 96,4%. Encontramos uma taxa global de complicações de 2,3%, sendo que 75% delas foram de natureza hemorrágica. Não verificamos a ocorrência de óbitos dentro do período de observação pós-biópsia. CONCLUSÃO: A utilização de agulhas calibrosas, parece, de fato, estar relacionada à melhoria na acurácia diagnóstica, com baixas taxas de complicações, sobretudo as hemorrágicas, contudo não letais. No presente trabalho, a idade mostrou-se um fator modificador da acurácia.


Subject(s)
Humans , Male , Female , Adult , Aged , Aged, 80 and over , Ultrasonography, Interventional/methods , Image-Guided Biopsy/methods , Liver/pathology , Liver Neoplasms/pathology , Postoperative Complications , Cross-Sectional Studies , Reproducibility of Results , Ultrasonography, Interventional/adverse effects , Biopsy, Large-Core Needle , Image-Guided Biopsy/adverse effects , Liver/diagnostic imaging , Liver Neoplasms/diagnostic imaging , Middle Aged , Neoplasm Metastasis
13.
Prensa méd. argent ; 104(6): 295-298, Ago2018. fig, graf
Article in Spanish | LILACS, BINACIS | ID: biblio-1051313

ABSTRACT

Renal biopsy is a key procedure for the evaluation and management of the renal diseases, in order to establish a certainty diagnosis, to perform an adequate treatment and to determine the prognosis, while it results in a fundamental tool, but not all the medical centers have the necessary requeriments to carry them succesfully so that it can achieve the maximum benefit, lessen the posible complications, since as it is an invasive technique, always exists a certain risk inherent to the procedure, being the technique of choice the percutaneous renal biopsy guided by ultrasound. The aim of this report, is to know the incidence of the reanl pathology, in kidney biopsies in our Hospita, between July 2008 through July 2017, by mean of a descriptive and retrospective study. Two-thousands and eightsi-six reanl biopsies were analyzed in that period, and we analyzed the frequency of the disease diagnosed, the origin of the samples and thir quality, the age range of the population studied, as well as the complications of the method employed


Subject(s)
Humans , Pathology, Clinical , Minimally Invasive Surgical Procedures , Image-Guided Biopsy/methods , Kidney/pathology , Kidney Diseases/diagnosis
14.
J. bras. pneumol ; 44(4): 307-314, July-Aug. 2018. tab, graf
Article in English | LILACS | ID: biblio-975920

ABSTRACT

ABSTRACT Objective: To evaluate the diagnostic accuracy of CT-guided percutaneous core needle biopsy (CT-CNB) of pulmonary nodules ≤ 2 cm, as well as to identify factors influencing the accuracy of the procedure and its morbidity. Methods: This was a retrospective, single-center study of 170 consecutive patients undergoing CT-CNB of small pulmonary nodules (of ≤ 2 cm) between January of 2010 and August of 2015. Results: A total of 156 CT-CNBs yielded a definitive diagnosis, the overall diagnostic accuracy being 92.3%. Larger lesions were associated with a higher overall accuracy (OR = 1.30; p = 0.007). Parenchymal hemorrhage occurring during the procedure led to lower accuracy rates (OR = 0.13; p = 0.022). Pneumothorax was the most common complication. A pleura-to-lesion distance > 3 cm was identified as a risk factor for pneumothorax (OR = 16.94), whereas performing a blood patch after biopsy was a protective factor for pneumothorax (OR = 0.18). Conclusions: Small nodules (of < 2 cm) represent a technical challenge for diagnosis. CT-CNB is an excellent diagnostic tool, its accuracy being high.


RESUMO Objetivo: Avaliar a precisão diagnóstica da biópsia percutânea com agulha grossa, guiada por TC - doravante denominada BAG-TC - de nódulos pulmonares ≤ 2 cm, bem como identificar fatores que influenciam a precisão do procedimento e sua morbidade. Métodos: Estudo retrospectivo, realizado em um único centro, com 170 pacientes consecutivos submetidos a BAG-TC de nódulos pulmonares pequenos (≤ 2 cm) entre janeiro de 2010 e agosto de 2015. Resultados: Do total de biópsias, 156 resultaram em diagnóstico definitivo, com precisão diagnóstica global de 92,3%. Lesões maiores estiveram relacionadas com maior precisão global (OR = 1,30; p = 0,007). A presença de hemorragia parenquimatosa durante o procedimento resultou em menor precisão (OR = 0,13; p = 0,022). Pneumotórax foi a complicação mais comum. Uma distância > 3 cm entre a lesão e a pleura foi identificada como fator de risco de pneumotórax (OR = 16,94), ao passo que a realização de tampão sanguíneo após a biópsia foi um fator de proteção contra o pneumotórax (OR = 0,18). Conclusões: O diagnóstico de nódulos pequenos (< 2 cm) é um desafio do ponto de vista técnico. A BAG-TC é uma excelente ferramenta diagnóstica, cuja precisão é alta.


Subject(s)
Humans , Male , Female , Child, Preschool , Child , Adolescent , Adult , Middle Aged , Aged , Aged, 80 and over , Young Adult , Pneumothorax/etiology , Multiple Pulmonary Nodules/pathology , Biopsy, Large-Core Needle/methods , Image-Guided Biopsy/methods , Lung Neoplasms/pathology , Tomography, X-Ray Computed , Retrospective Studies , Risk Factors , Solitary Pulmonary Nodule/pathology , Biopsy, Large-Core Needle/adverse effects , Image-Guided Biopsy/adverse effects , Hemorrhage/etiology
15.
Colomb. med ; 49(2): 164-168, Apr.-June 2018. tab
Article in English | LILACS | ID: biblio-952910

ABSTRACT

Abstract Objectives: To investigate serum and urine levels of Alpha-methylacyl-CoA-racemase (AMACR) and Netrin 1 in patients with and without prostate cancer and to determine whether these markers could be used as alternatives in diagnosis of prostate cancer instead of serum prostate specific antigen (PSA) levels. Methods: One hundred and seventy five patients between 45-75 years to whom transrectal ultrasound guided biopsies were performed for abnormal serum PSA levels or digital rectal examinations were included. The levels of AMACR and Netrin 1 levels of blood and urine samples of 5 mL those were taken prior to biopsies were measured. . Results: The mean age of the patients was 62.7 ±6.4 years. Prostate cancer was detected in 40 patients (22.8%) while 135 of them (77.2%) were diagnosed as benign prostate hyperplasia (BPH). In BPH group, serum and urine levels of AMACR and Netrin 1 were 13.4 ±16.9 ng/mL; 7.1 ±3.4 ng/mL; 164.1±46 pg/mL and 19.5 ±5.0 pg/mL respectively. The levels of serum and urine levels of AMACR and Netrin 1 were 10.2 ±9.8 ng/mL; 6.8 ±2.5 ng/mL; 159.1 ±44.1 pg/mL and 20.1 ±5.3 pg/mL respectively in prostate cancer group. There was no statistically significant difference or correlation between these two groups serum and urine AMACR and Netrin 1 results Conclusions: Serum and urine levels of AMACR and Netrin 1 were not found to be alternatives for serum PSA levels in the diagnosis of prostate cancer in this study.


Resumen Objetivos: Investigar los niveles de alfa-metil acilcoenzima-A y Netrina 1 en pacientes con y sin cáncer de próstata y determinar si estos marcadores pueden ser usados como una alternativa en el diagnóstico de cáncer de próstata en lugar del antígeno prostático específico en suero (PSA). Métodos: Fueron incluidos 175 pacientes entre 45-75 años, a quienes se les realizó una biopsia de próstata guiada por ultrasonido por presentar un nivel anormal de PSA en el suero o un tacto rectal. Se tomó una muestra de 5 mL de sangre y orina para medir los niveles de alfa-metil acilcoenzima-A y Netrina 1. Estos niveles se midieron antes del análisis de la biopsia. Resultados: La edad media de los pacientes fue de 62.7±6.4 años. Se detectó cander en 40 pacientes (22.8%), mientras que a 135 de ellos (77.2%) se les diagnóstico una hiperplasia benigna de próstata (HBP). En el grupo HBP los niveles en suero y orina de alfa-metil acilcoenzima-A y Netrina 1 fueron 13.4 ±16.9 ng/mL; 7.1 ±3.4 ng/mL; 164.1 ±46 pg/mL y 19.5 ±5.0 pg/mL respectivamente. En el grupo con cáncer de próstata los niveles en suero y orina de alfa-metil acilcoenzima-A y Netrina 1 fueron 10.2 ±9.8 ng/mL; 6.8 ±2.5 ng/mL; 159.1 ±44.1 pg/mL y 20.1 ±5.3 pg/mL respectivamente. No hubo una diferencia significativa o una correlación entre los niveles de alfa-metil acilcoenzima-A y Netrina 1 en suero y orina al comparar estos dos grupos de pacientes. Conclusiones: Los niveles de alfa-metil acilcoenzima-A y Netrina 1 en suero y orina no son una alternativa para reemplazar el PSA en suero para el diagnóstico de cáncer de próstata.


Subject(s)
Aged , Humans , Male , Middle Aged , Prostatic Neoplasms/diagnosis , Prostate-Specific Antigen/blood , Racemases and Epimerases/analysis , Netrin-1/analysis , Prostatic Neoplasms/urine , Prostatic Neoplasms/blood , Biomarkers, Tumor/urine , Biomarkers, Tumor/blood , Ultrasonography, Interventional/methods , Racemases and Epimerases/urine , Racemases and Epimerases/blood , Image-Guided Biopsy/methods , Netrin-1/urine , Netrin-1/blood
17.
Int. braz. j. urol ; 44(1): 192-195, Jan.-Feb. 2018. graf
Article in English | LILACS | ID: biblio-892936

ABSTRACT

ABSTRACT The biochemical recurrence after local treatment for prostate cancer is an often challenging condition of clinical management. The aim of this report is to demonstrate the importance of the association of various imaging methods in the identification and subsequent accurate percutaneous biopsy in patients with recurrence of prostate cancer, especially in unusual sites. An 86 years old male with biochemical recurrence, during radiological investigation a PET-MRI was noted the presence of an asymmetry of the vas deferens with PSMA-68Ga uptaken, suggesting the recurrence. A percutaneous fusion biopsy with PET-MRI and ultrasound was performed using transrectal access using ultrasound confirming infiltrating adenocarcinoma of the wall of the vas deferens, compatible with neoplastic prostate recurrence. The fusion image technique combines the real-time view of the US to the possibility of higher definition and higher specificity, methods more anatomical detail as tomography and magnetic resonance imaging, simultaneously. High resolution acquired in PET / MR associated with image fusion allows orientation procedures, even in areas of difficult access, with greater accuracy than conventional techniques.


Subject(s)
Humans , Male , Aged , Prostatic Neoplasms/diagnostic imaging , Adenocarcinoma/diagnostic imaging , Ultrasonography, Interventional/methods , Image-Guided Biopsy/methods , Neoplasm Recurrence, Local/diagnostic imaging , Prostatectomy , Prostatic Neoplasms/surgery , Prostatic Neoplasms/pathology , Magnetic Resonance Imaging , Adenocarcinoma/surgery , Adenocarcinoma/pathology , Tomography, X-Ray Computed , Ultrasonography , Neoplasm Recurrence, Local/surgery , Neoplasm Recurrence, Local/pathology
18.
Rev. argent. urol. (1990) ; 83(3): 102-108, 2018. tab, ilus
Article in Spanish | LILACS | ID: biblio-986349

ABSTRACT

Objetivos: Analizar la performance diagnóstica de la punción biopsia prostática (PBP) guiada mediante ecografía con fusión de imágenes de resonancia magnética (RM) para la detección del cáncer de próstata (CP) en pacientes con biopsia previa negativa. Materiales y métodos: Se analizaron todas las PBP transrrectales dirigidas bajo ecografía con fusión de imágenes de RM en pacientes mayores de 40 años de edad con sospecha de CP y biopsia previa randomizada negativa efectuadas durante el período comprendido entre enero de 2015 y enero de 2018. Se calculó la sensibilidad, especificidad, valor predictivo positivo y negativo de dicho procedimiento. Resultados: De un total de 40 pacientes, 25 cumplieron los criterios de inclusión. La PBP transrrectal guiada bajo ecografía con fusión de imágenes de RM presentó una sensibilidad del 90% en la detección de CP clínicamente significativo (CPsig), mostrando una mejoría en la detección del 20% respecto de la biopsia randomizada. Conclusiones: La PBP transrrectal guiada con ecografía y fusión de imágenes de RM mejora la performance en la detección de CPsig en pacientes con biopsia previa negativa(AU)


Objective: To analyze the diagnostic performance of transrectal prostate US (ultrasonography) guided biopsy with magnetic resonance imaging (MRI) fusion in the detection of prostate cancer in patients with negative previous biopsy. Materials and methods: Between January 2015 to January 2018, transrectal prostate biopsies under US guided with MRI fusion were performed in patients older than 40 years with suspicion of prostate cancer and prior negative biopsy. Sensitivity, specificity, positive and negative predictive value of the procedure were analyzed. Results: Out of a total of 40 patients, 25 met the inclusion criteria. Transrectal prostate US guided biopsy with MRI fusion presented a sensitivity of 90%, showing an improvement of 20% in the clinically significant prostate cancer detection compared with randomized biopsy. Conclusions: Transrectal prostate US guided biopsy with MRI fusion showed high performance in the detection of significative prostate cancer in patients with negative previous biopsy(AU)


Subject(s)
Male , Adult , Middle Aged , Aged , Prostatic Neoplasms/diagnostic imaging , Magnetic Resonance Imaging/methods , Ultrasonography , Image-Guided Biopsy/instrumentation , Image-Guided Biopsy/methods , Prostate/diagnostic imaging , Prostatic Neoplasms/pathology , Rectum , Cross-Sectional Studies
19.
Einstein (Säo Paulo) ; 16(2): eMD4408, 2018. graf
Article in English | LILACS | ID: biblio-953159

ABSTRACT

ABSTRACT Magnetic resonance imaging of the prostate is an imaging method that has shown increasing relevance in urological practice. Due to technological evolution of scanners and the introduction of functional sequences, it has enabled greater accuracy in detection and characterization of prostate tumors.


RESUMO A ressonância magnética de próstata é um método de imagem que tem demonstrado crescente relevância na prática urológica. Devido aos avanços tecnológicos dos equipamentos e à introdução de sequências funcionais, possibilita maior acurácia na detecção e caracterização de tumores prostáticos.


Subject(s)
Humans , Male , Prostatic Neoplasms/diagnostic imaging , Magnetic Resonance Imaging/methods , Sensitivity and Specificity , Magnetic Resonance Imaging, Interventional , Image-Guided Biopsy/methods
20.
Ethiop. med. j. (Online) ; 56(1): 3-10, 2018.
Article in English | AIM | ID: biblio-1261993

ABSTRACT

Background: The introduction of image-guided biopsy has revolutionized the quality of patient care by avoiding open and complications associated with it and the use anesthesia. Even though Ethiopian radiological training dates back to more than two decades, interventional radiology is a very recent introduction. This study reports the safety and significance of image guided biopsy on patient care.Patients and methods: This study was a prospective study carried out to assess the impact and safety of doing image-guided biopsy in a tertiary care teaching Hospital in Addis Ababa, Ethiopia.Results: A total of 117 patients, their age ranging from 3 to 80years and a mean age of 41 were evaluated; 6.8% of them were children below the age of 10. Around two-thirds of the cases had intra-abdominal indications for biopsy followed by mediastinal pathologies. Ultrasound was used as a guide in about 85% of the cases. Except for one case that developed massive hemoptysis following fine needle aspiration of a middle mediastinal mass and treated conservatively, there was no major complication. A few minor complications, like mild pain and minor hemorrhage, required only close observation.Conclusion: On the whole, our study indicates that image-guide biopsy improves the existing medical care.Moreover, institutions particularly those providing training in radiology should promote the establishment of interventional radiology for better patient diagnosis and improved planning of subsequent treatment


Subject(s)
Image-Guided Biopsy/methods , Patient Care , Safety
SELECTION OF CITATIONS
SEARCH DETAIL